[doc] update VASP interface doc for new interface features
This commit is contained in:
parent
7b8b3dd055
commit
dbbbf020fa
doc/guide
@ -8,7 +8,7 @@ The VASP interface relies on new options introduced since version 5.4.x In
|
|||||||
particular, a new INCAR-option `LOCPROJ
|
particular, a new INCAR-option `LOCPROJ
|
||||||
<https://cms.mpi.univie.ac.at/wiki/index.php/LOCPROJ>`_, the new `LORBIT` modes
|
<https://cms.mpi.univie.ac.at/wiki/index.php/LOCPROJ>`_, the new `LORBIT` modes
|
||||||
13 and 14 have been added, and the new `ICHARG` mode 5 for charge
|
13 and 14 have been added, and the new `ICHARG` mode 5 for charge
|
||||||
self-consistent DFT+DMFT calculations have been added.
|
self-consistent DFT+DMFT calculations have been added. The VASP interface for charge self-consistent calculations is officially supported as of VASP version 6.5.0 (see `VASP ICHARG=5 documentation <https://www.vasp.at/wiki/index.php/ICHARG>`_). It is highly recommended to compile VASP with hdf5 support enabled (`-DVASP_HDF5`) to enable features of the interface. This allows to use the interface while symmetries are switched on in VASP, and enables spin-polarized feedback in charge self-consistent calculations to VASP.
|
||||||
|
|
||||||
The VASP interface methodologically builds on the so called projection on
|
The VASP interface methodologically builds on the so called projection on
|
||||||
localized orbitals (PLO) scheme, where the resulting KS states from DFT are
|
localized orbitals (PLO) scheme, where the resulting KS states from DFT are
|
||||||
@ -18,26 +18,16 @@ The implementation is presented in `M. Schüler et al. 2018 J. Phys.: Condens.
|
|||||||
Matter 30 475901 <https://doi.org/10.1088/1361-648X/aae80a>`_.
|
Matter 30 475901 <https://doi.org/10.1088/1361-648X/aae80a>`_.
|
||||||
|
|
||||||
The interface consists of two parts, :py:mod:`PLOVASP<triqs_dft_tools.converters.plovasp>`, a collection of
|
The interface consists of two parts, :py:mod:`PLOVASP<triqs_dft_tools.converters.plovasp>`, a collection of
|
||||||
python classes and functions converting the raw VASP output to proper projector
|
python classes and functions converting the VASP output to proper projector
|
||||||
functions, and the python based :py:mod:`VaspConverter<triqs_dft_tools.converters.vasp>`, which
|
functions, and the python based :py:mod:`VaspConverter<triqs_dft_tools.converters.vasp>`, which
|
||||||
creates a h5 archive from the :py:mod:`PLOVASP<triqs_dft_tools.converters.plovasp>` output readable by
|
creates a h5 archive from the :py:mod:`PLOVASP<triqs_dft_tools.converters.plovasp>` output readable by
|
||||||
`SumkDFT`. Therefore, the conversion consist always of two steps.
|
`SumkDFT`. Therefore, the conversion consist always of two steps.
|
||||||
|
|
||||||
Here, we will present a guide how the interface `can` be used to create input for a DMFT calculation, using SrVO3 as an example. Full examples can be found in the :ref:`tutorial section of DFTTools<tutorials>`.
|
Here, we will present a guide how the interface `can` be used to create input for a DMFT calculation, using SrVO3 as an example. Full examples can be found in the :ref:`tutorial section of DFTTools<tutorials>`.
|
||||||
|
|
||||||
Limitations of the interface
|
For VASP version older than 6.5.0 there are a few limitation of the interface as it was not officially supported and only text file based. See `Remarks for VASP older than 6.5.0`_ for details.
|
||||||
============================
|
|
||||||
|
|
||||||
* The interface works correctly only if the k-point symmetries
|
Generation of projectors for k-point lines (option `Lines` in KPOINTS) needed for Bloch spectral function calculations is not possible at the moment.
|
||||||
are turned off during the VASP run (ISYM=-1).
|
|
||||||
* Generation of projectors for k-point lines (option `Lines` in KPOINTS)
|
|
||||||
needed for Bloch spectral function calculations is not possible at the moment.
|
|
||||||
* The interface currently supports only collinear-magnetism calculation
|
|
||||||
(this implies no spin-orbit coupling) and spin-polarized projectors have not
|
|
||||||
been tested.
|
|
||||||
* The converter needs the correct Fermi energy from VASP, which is read from
|
|
||||||
the LOCPROJ file. However, VASP by default does not output this information.
|
|
||||||
Please see `Remarks on the VASP version`_.
|
|
||||||
|
|
||||||
VASP: generating raw projectors
|
VASP: generating raw projectors
|
||||||
===============================
|
===============================
|
||||||
@ -383,16 +373,20 @@ For two correlated sites, one can define the file as follows:
|
|||||||
0.0 1.0 0.0 0.0 0.0
|
0.0 1.0 0.0 0.0 0.0
|
||||||
0.0 0.0 0.0 1.0 0.0
|
0.0 0.0 0.0 1.0 0.0
|
||||||
|
|
||||||
Remarks on the VASP version
|
Remarks for VASP older than 6.5.0
|
||||||
===============================
|
=================================
|
||||||
|
|
||||||
In the current version of the interface the Fermi energy is extracted from the
|
The above mentioned interface has some limitations for VASP versions older than 6.5.0:
|
||||||
DOSCAR. However, if one pursues to do charge self-consistent calculations one
|
|
||||||
needs to write the Fermi energy to the projectors (`LOCPROJ` file), as the DOSCAR
|
* The interface works correctly only if the k-point symmetries
|
||||||
is only updated after a full SCF/NSCF run. The file should contain the Fermi energy
|
are turned off during the VASP run (ISYM=-1).
|
||||||
in the header. One can either copy the Fermi energy manually there after a successful
|
* The interface currently supports only collinear-magnetism calculation
|
||||||
VASP run, or modify the VASP source code slightly, by replacing the following line in
|
(this implies no spin-orbit coupling) and spin-polarized projectors have not
|
||||||
`locproj.F` (around line 695):
|
been tested.
|
||||||
|
* The converter needs the correct Fermi energy from VASP, which is read from
|
||||||
|
the LOCPROJ file. However, VASP by default does not output this information.
|
||||||
|
|
||||||
|
For VASP older than 6.5.0 the Fermi level cannot be extracted from the `vaspout.h5` file, then interface falls back to extract the Fermi level from the DOSCAR. However, if one pursues to do charge self-consistent calculations one needs to write the Fermi energy to the projectors (`LOCPROJ` file), as the DOSCAR is only updated after a full SCF/NSCF run. The file should contain the Fermi energy in the header. One can either copy the Fermi energy manually there after a successful VASP run, or modify the VASP source code slightly, by replacing the following line in `locproj.F` (around line 695):
|
||||||
::
|
::
|
||||||
|
|
||||||
< WRITE(99,'(4I6," # of spin, # of k-points, # of bands, # of proj" )') NS,NK,NB,NF
|
< WRITE(99,'(4I6," # of spin, # of k-points, # of bands, # of proj" )') NS,NK,NB,NF
|
||||||
@ -417,7 +411,6 @@ Next, we need to pass this option when calling from `electron.F` and `main.F`
|
|||||||
|
|
||||||
Now Vasp should print in the header of the `LOCPROJ` file additionally the Fermi energy.
|
Now Vasp should print in the header of the `LOCPROJ` file additionally the Fermi energy.
|
||||||
|
|
||||||
|
|
||||||
Another critical point for CSC calculations is the function call of
|
Another critical point for CSC calculations is the function call of
|
||||||
`LPRJ_LDApU` in VASP. This function is not needed, and was left there for debug
|
`LPRJ_LDApU` in VASP. This function is not needed, and was left there for debug
|
||||||
purposes, but is called every iteration. Removing the call to this function in `electron.F` in line 644 speeds up the calculation significantly in the `ICHARG=5` mode. Moreover, this prevents VASP from generating the `GAMMA` file, which should ideally only be done by the DMFT code after a successful DMFT step, and then be read by VASP.
|
purposes, but is called every iteration. Removing the call to this function in `electron.F` in line 644 speeds up the calculation significantly in the `ICHARG=5` mode. Moreover, this prevents VASP from generating the `GAMMA` file, which should ideally only be done by the DMFT code after a successful DMFT step, and then be read by VASP.
|
||||||
|
@ -133,8 +133,8 @@ Once VASP reaches the point where the projectors are generated
|
|||||||
it creates a lock file `vasp.lock` and waits until the lock file is
|
it creates a lock file `vasp.lock` and waits until the lock file is
|
||||||
removed. The shell script, in turn, waits for the VASP process and once
|
removed. The shell script, in turn, waits for the VASP process and once
|
||||||
the lock file is created it starts a DMFT iteration. The DMFT iteration
|
the lock file is created it starts a DMFT iteration. The DMFT iteration
|
||||||
must finish by generating a Kohn-Sham (KS) density matrix (file `GAMMA`)
|
must finish by generating a Kohn-Sham (KS) density matrix (file `GAMMA` or `vaspgamma.h5`)
|
||||||
and removing the lock file. The VASP process then reads in `GAMMA`
|
and removing the lock file. The VASP process then reads in `GAMMA`/`vaspgamma.h5`
|
||||||
and proceeds with the next iteration. PLOVasp interface provides a shell-script :program:`vasp_dmft` (in the triqs bin directory)::
|
and proceeds with the next iteration. PLOVasp interface provides a shell-script :program:`vasp_dmft` (in the triqs bin directory)::
|
||||||
|
|
||||||
vasp_dmft [-n <number of cores>] -i <number of iterations> -j <number of VASP iterations with fixed charge density> [-v <VASP version>] [-p <path to VASP directory>] [<dmft_script.py>]
|
vasp_dmft [-n <number of cores>] -i <number of iterations> -j <number of VASP iterations with fixed charge density> [-v <VASP version>] [-p <path to VASP directory>] [<dmft_script.py>]
|
||||||
@ -162,7 +162,7 @@ calculations with the main difference that its functionality (apart from the
|
|||||||
lines importing other modules) should be placed inside a function `dmft_cycle()`
|
lines importing other modules) should be placed inside a function `dmft_cycle()`
|
||||||
which will be called every DMFT cycle and returns both the correlation energy and the SumK object.
|
which will be called every DMFT cycle and returns both the correlation energy and the SumK object.
|
||||||
|
|
||||||
VASP has a special INCAR `ICHARG=5` mode, that has to be switched on to make VASP wait for the `vasp.lock` file, and read the updated charge density after each step. One should add the following lines to the `INCAR` file::
|
VASP has a special INCAR `ICHARG=5 <https://www.vasp.at/wiki/index.php/ICHARG>`_ mode, that has to be switched on to make VASP wait for the `vasp.lock` file, and read the updated charge density after each step. One should add the following lines to the `INCAR` file::
|
||||||
|
|
||||||
ICHARG = 5
|
ICHARG = 5
|
||||||
NELM = 1000
|
NELM = 1000
|
||||||
@ -170,6 +170,7 @@ VASP has a special INCAR `ICHARG=5` mode, that has to be switched on to make VAS
|
|||||||
IMIX=1
|
IMIX=1
|
||||||
BMIX=0.5
|
BMIX=0.5
|
||||||
AMIX=0.02
|
AMIX=0.02
|
||||||
|
LSYNCH5=True
|
||||||
|
|
||||||
Technically, VASP runs with `ICHARG=5` in a SCF mode, and adding the DMFT
|
Technically, VASP runs with `ICHARG=5` in a SCF mode, and adding the DMFT
|
||||||
changes to the DFT density in each step, so that the full DFT+DMFT charge
|
changes to the DFT density in each step, so that the full DFT+DMFT charge
|
||||||
@ -187,6 +188,8 @@ To understand the difference please make sure to read `ISTART flag VASP wiki
|
|||||||
`NELMIN` ensure that VASP does not terminate after the default number of
|
`NELMIN` ensure that VASP does not terminate after the default number of
|
||||||
iterations of 60.
|
iterations of 60.
|
||||||
|
|
||||||
|
The `LSYNCH5` flag is set to `True` to ensure that the VASP writte vaspout.h5 file can be read while VASP is running. Starting from VASP 6.5.0 all communication between VASP and TRIQS is performed through two h5 files: `vaspout.h5 <https://www.vasp.at/wiki/index.php/Vaspout.h5>`_ and `vaspgamma.h5 <https://www.vasp.at/wiki/index.php/Vaspgamma.h5>`_ when VASP is compiled with hdf5 support.
|
||||||
|
|
||||||
For more detailed and fine grained methods to run Vasp in CSC also on clusters see the methods implemented in `solid dmft <https://triqs.github.io/solid_dmft/_ref/dft_managers.html>`_.
|
For more detailed and fine grained methods to run Vasp in CSC also on clusters see the methods implemented in `solid dmft <https://triqs.github.io/solid_dmft/_ref/dft_managers.html>`_.
|
||||||
|
|
||||||
|
|
||||||
|