mirror of
https://github.com/triqs/dft_tools
synced 2025-05-01 04:34:57 +02:00
[doc] add measure_density_matrix to all cthyb tutorial using tail_fit
This commit is contained in:
parent
864267ef8a
commit
74f013e63b
@ -49,6 +49,9 @@ p["perform_tail_fit"] = True
|
||||
p["fit_max_moment"] = 4
|
||||
p["fit_min_w"] = 4.0
|
||||
p["fit_max_w"] = 8.0
|
||||
# measure impurity density matrix to get self-energy moments for improved tail fit
|
||||
p["measure_density_matrix"] = True
|
||||
p["use_norm_as_weight"] = True
|
||||
|
||||
# double counting correction:
|
||||
dc_type = 0 # FLL
|
||||
|
@ -52,6 +52,9 @@ p["perform_tail_fit"] = True
|
||||
p["fit_max_moment"] = 4
|
||||
p["fit_min_n"] = 30
|
||||
p["fit_max_n"] = 70
|
||||
# measure impurity density matrix to get self-energy moments for improved tail fit
|
||||
p["measure_density_matrix"] = True
|
||||
p["use_norm_as_weight"] = True
|
||||
|
||||
# double counting correction:
|
||||
dc_type = 0 # FLL
|
||||
|
@ -43,6 +43,9 @@ p["perform_tail_fit"] = True
|
||||
p["fit_max_moment"] = 4
|
||||
p["fit_min_n"] = 30
|
||||
p["fit_max_n"] = 60
|
||||
# measure impurity density matrix to get self-energy moments for improved tail fit
|
||||
p["measure_density_matrix"] = True
|
||||
p["use_norm_as_weight"] = True
|
||||
|
||||
# If conversion step was not done, we could do it here. Uncomment the lines it you want to do this.
|
||||
#from triqs_dft_tools.converters.wien2k import *
|
||||
|
@ -73,6 +73,7 @@ p["fit_max_moment"] = 4
|
||||
p["fit_min_w"] = 20
|
||||
p["fit_max_w"] = 30
|
||||
p["perform_tail_fit"] = True
|
||||
# measure impurity density matrix to get self-energy moments for improved tail fit
|
||||
p["measure_density_matrix"] = True
|
||||
p["use_norm_as_weight"] = True
|
||||
|
||||
|
@ -79,10 +79,10 @@ def dmft_cycle():
|
||||
p["fit_min_w"] = 20
|
||||
p["fit_max_w"] = 30
|
||||
p["perform_tail_fit"] = True
|
||||
# measure impurity density matrix to get self-energy moments for improved tail fit
|
||||
p["measure_density_matrix"] = True
|
||||
p["use_norm_as_weight"] = True
|
||||
|
||||
|
||||
# Double Counting: 0 FLL, 1 Held, 2 AMF
|
||||
DC_type = 0
|
||||
DC_value = 59.0
|
||||
|
@ -158,6 +158,9 @@ Now we have the interaction Hamiltonian for the solver, which we set up next::
|
||||
p["fit_max_moment"] = 4
|
||||
p["fit_min_n"] = 40
|
||||
p["fit_max_n"] = 100
|
||||
# measure impurity density matrix to get self-energy moments for improved tail fit
|
||||
p["measure_density_matrix"] = True
|
||||
p["use_norm_as_weight"] = True
|
||||
|
||||
|
||||
The DMFT loop with automatic basis rotations
|
||||
|
@ -156,6 +156,9 @@ Now we have the interaction Hamiltonian for the solver, which we set up next::
|
||||
p["fit_max_moment"] = 4
|
||||
p["fit_min_w"] = 4.0
|
||||
p["fit_max_w"] = 8.0
|
||||
# measure impurity density matrix to get self-energy moments for improved tail fit
|
||||
p["measure_density_matrix"] = True
|
||||
p["use_norm_as_weight"] = True
|
||||
|
||||
|
||||
The DMFT loop with automatic basis rotations
|
||||
|
@ -124,6 +124,9 @@ of parameters for a first guess is::
|
||||
p["fit_max_moment"] = 4
|
||||
p["fit_min_n"] = 30
|
||||
p["fit_max_n"] = 60
|
||||
# measure impurity density matrix to get self-energy moments for improved tail fit
|
||||
p["measure_density_matrix"] = True
|
||||
p["use_norm_as_weight"] = True
|
||||
|
||||
Here we use a tail fit to deal with numerical noise of higher Matsubara frequencies.
|
||||
For other options and more details on the solver parameters, we refer the user to
|
||||
|
@ -85,6 +85,9 @@ We also have to specify the `CTHYB solver <https://triqs.github.io/cthyb/latest>
|
||||
p["fit_max_moment"] = 4
|
||||
p["fit_min_n"] = 30
|
||||
p["fit_max_n"] = 60
|
||||
# measure impurity density matrix to get self-energy moments for improved tail fit
|
||||
p["measure_density_matrix"] = True
|
||||
p["use_norm_as_weight"] = True
|
||||
|
||||
Here we use a tail fit to deal with numerical noise of higher Matsubara frequencies. For other options and more details on the solver parameters, we refer to the `CTHYB solver <https://triqs.github.io/cthyb/latest/reference/constr_parameters.html>`_ documentation. It is important to note that the solver parameters have to be adjusted for each material individually. A guide on how to set the tail fit parameters is given :ref:`below <tailfit>`.
|
||||
|
||||
|
Loading…
x
Reference in New Issue